Keba P30

This page describes how to connect a Keba P30 charging station to the SOLARWATT Manager.
Table of contents

    Compatibility

     EnergyManager proSOLARWATT Manager
    (flex 1.0 / flex 1.5 / rail)
    KeContact
    P30 Green Edition 
    c-series

     

     

    KeContact
    P30 Green Edition 
    x-series

     

     

    KeContact
    P30 Green Edition 
    Dienstwagenwallbox

     

     

    KeContact
    P30 Green Edition 
    PV Edition

     

     

    KeContact
    P30 Green Edition 
    a-series

     

     

    KeContact
    P30 Green Edition 
    Deutschlandedition

     

     

     

     

    Full compatibility

     

    No compatibility

    Possible number of controlled charging stations in the energy management system

     EnergyManager proSOLARWATT Manager
    (flex 1.0 / flex 1.5 / rail)
    Keba13
    Webasto
    (Live/Next)
    11
    Alfen13

     

     

    Installation and configuration

    Interface: Ethernet

    Applicable documents

    Prerequisites

    • The charging pole is installed according to the KEBA Installation instructions.
    • The charging pole is connected to the local network via the Ethernet1 connection X4 of the KEBA (LSA+ fixed cabling).

    Configuration for the Manager

    • Set the dip switch DSW1.3 to activate the UDP interface. This enables communication with the Manager flex.
    • After setting the dip switch DSW1.3, you must restart the KEBA charging pole (disconnect the power supply) for the changes to take effect.

    Device search in SmartSetup

    Certain device types are found and installed automatically(Automatic installation)

    Other device types must be installed by selecting the device driver and specifying the IP address or host name(manual installation).

    Information on the installation types can be found in the table below.

    Automatic installation

    If the device is correctly configured and available in the network, it is displayed in green in the device list.

    Manual installation

    • Select Select devices in the drop-down menu or search for the corresponding entry according to the table below.
    • Enter the required specifications according to the table below:
      • Search mode
      • iP address or host name, if applicable
    • Click Add device to search.
    • If necessary, add further devices to the search.
    • Once you have added all the devices to be searched for, click Search for and install devices.

    You can recognize correctly installed devices by the message: Device is installed. in the device list. The list also shows the current creation data.

    Driver selection for device search

     energyManager proSOLARWATT Manager
    (flex 1.0 / flex 1.5 / rail)
     DriverSearch mode  
    Keba KeContact
    P30
    KEBA KeContact P20/P30Search and install deviceAutomatic installation

    Troubleshooting

    If the device is not found via the automatic search / automatic IP detection, check

    • whether the device is available in the local network (via network scan - note, a network scan requires the prior consent of your customer - or access to the local user interface of the router).
    • whether the dip switch 1.2 has been set and the charging station has then been restarted. In rare cases, it may be necessary to set the dip switch several times, each time in conjunction with a restart of the charging pole.

    PV optimization settings

    Additional settings are required to operate the device with a maximum proportion of solar power (PV optimization).

    The settings for PV optimization are made in the SOLARWATT Manager portal under Optimizer.